fbpx

Our customer service and DesignLINK teams are closed from 12pm on 19th December and reopen on Monday 6th January. We wish you a safe break and Happy New Year.

Apartments

Whether you’re a developer, architect, designer, builder or wall installer, Hebel wall systems deliver exceptional advantages in terms of quality, project efficiency, risk minimisation and cost and time certainty.


Hebel systems deliver a holistic solution for high rise apartments, hotels, student accommodation and commercial projects that no other systems can match.

Building with Hebel benefits all stakeholders in the project lifecycle through its role in value-adding to the project’s quality, design and construction efficiency, minimising risk and providing cost and time certainty.

NEW Hebel Service Panel

Learn more about our NEW pre-made machined panel that meets compliance requirements and works seamlessly with Hebel’s innovative corridor wall system.

View Product

Applications

Specification Tool
  • Intertenancy Walls
  • Corridor Walls
  • Shaft Walls
  • Services Walls
  • High Rise Facades
  • Balcony Blades
  • Floors

Hebel Systems

Intertenancy Walls

Hebel Intertenancy Wall Systems provide solid and secure walls that maximise floorspace, minimise costs and risks – while delivering long-term value.

These systems are simple to specify with only two types of plasterboard lining to be considered for most system types – standard or moisture resistant.

Hebel Intertenancy Wall Systems include walls with concealed water services on one side and both sides, with a system for large services applications such as shower mixers in both apartments – all maximising floorspace.

Systems have also been specially designed by CSR Hebel for bathroom pods to provide maximum design efficiency, while minimising wall thickness. This is achieved through the combination of onsite constructed Hebel elements with off-site manufactured bathroom pod walls. The Hebel PowerPanel wall leaf construction is the fire-rated element and can be installed from one side only, while the two systems combined provide the acoustic performance.

Hebel Systems Overview Videos
System Application System code FRL Acoustic rating Wall width
label Intertenancy wall for concealed water services one side System code HEB 1072 Dry to Dry FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 50dB   Wall width 185mm
label Intertenancy wall for concealed water services one side System code HEB 1073 Dry to Wet FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 50dB Wall width 185mm
label Intertenancy wall for bathroom pod one side System code HEB 1451 Apartment to Bathroom pod FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr ≥50dB Wall width 178mm
label Intertenancy wall for concealed water services both sides System code HEB 1074 Dry to Dry FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 50dB   Wall width 243mm
label Intertenancy wall for concealed water services both sides System code HEB 1075 Dry to Wet FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 50dB   Wall width 228mm
label Intertenancy wall for concealed water services both sides System code HEB 1076 Wet to Wet FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 50dB Wall width 228mm
label Intertenancy wall for large concealed water services both sides System code HEB 1077 Dry to Dry FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 53dB   Wall width 269mm
label Intertenancy wall for large concealed water services both sides System code HEB 1078 Dry to Wet FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 53dB   Wall width 269mm
label Intertenancy wall for large concealed water services both sides System code HEB 1079 Wet to Wet FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 54dB Wall width 269mm
label Intertenancy wall for bathroom pod each side System code HEB 1452 Bathroom pod to Bathroom pod FRL -/90/90 for wall heights up to 3.3m Acoustic rating Rw+Ctr ≥50dB Wall width 235mm
label Intertenancy wall for concealed water services one side, bathroom pod other side System code HEB 1453 Apartment to Bathroom pod FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr ≥50dB Wall width 221mm

1 For wall heights higher than 3.3m, caged tongue & groove PowerPanel can be used and will achieve a FRL of -/120/120 for wall heights up to 4.65m (vertically).

Hebel Systems

Corridor Walls

Hebel Corridor Wall Systems maximise floor space and provide solid secure walls for services located on one side between common areas and apartments. These walls typically require a minimum sound insulation of Rw = 50 dB which Hebel Corridor Wall Systems easily achieve and a minimum fire rating level of -/60/60 – well-surpassed by CSR Hebel with a fire rating level of -/90/90 for wall heights up to 3.3 metres and -/120/120 for walls up to 4.65 metres (vertically) when caged tongue and groove PowerPanel is used.

CSR Hebel has also designed a hybrid system for corridor walls adjacent to bathroom pods making it easy for architects, designers and builders to specify the most economical systems for each pod project. This is achieved through the combination of onsite constructed Hebel elements with off-site manufactured bathroom pod walls. The Hebel PowerPanel wall leaf construction provides the fire rating and can be installed from one side only, while the two systems combined provide the acoustic performance. For construction, builders and contractors benefit from these well developed systems as they present a much clearer picture of which wall components are required to be built onsite and which elements are already integrated within the bathroom pod walls.

The new Hebel Service Panel is our latest product innovation, a pre-made machined panel that meets compliance requirements and works seamlessly with Hebel’s corridor wall system. Designed to the building’s specification, these pre-made machined panels reduce on-site cutting and drilling. Because they are custom made, they are designed to meet each project’s specific compliance requirements – improving the compliance reliability and build quality of multi-residential construction.

Hebel Systems Overview Videos

NEW Hebel Service PanelsHIGH-RISE INTERNAL WALLS


Introducing HebelService Panel 

Hebel PowerPanel Video

Hebel Service PanelMade to Spec.Ready to Install

Hebel PowerPanel Video
System Application System code FRL Acoustic rating Wall width
label Corridor wall for concealed water services one side System code HEB 1168 Dry to Dry FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw = 58dB Wall width 180mm
label Corridor wall for concealed water services one side System code HEB 1169 Dry to Wet FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw = 59dB Wall width 180mm
label Corridor wall for concealed water services one side with furring channel System code HEB 1170 Dry to Dry FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw = 52dB Wall width 144mm
label Corridor wall for concealed water services one side with furring channel System code HEB 1171 Dry to Wet FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw = 53d Wall width 144mm
label Corridor wall adjacent to bathroom pod System code HEB 1450 Corridor to Bathroom pod FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw ≥50dB Wall width 168mm

1 For wall heights higher than 3.3m, caged tongue & groove PowerPanel can be used and will achieve a FRL of -/120/120 for wall heights up to 4.65m (vertically).

Hebel Systems

Shaft Walls

Robust and proven Hebel Shaft Wall Systems maximise space utilisation and minimise risks and costs in construction. The shaft system for dry areas provides a solid, secure wall with a narrow width around service shafts to dry habitable areas and between scissor stairs. The system for wet areas is designed for general partitions between service shafts and wet areas or shafts adjacent to common areas.

For wall heights higher than 3.3m and up to 4.65m (vertical), caged tongue & groove PowerPanel can be used which will achieve a FRL of -/120/120. This panel can also be installed horizontally to a maximum panel length of 4800mm and to an unlimited height without the need for thin bed adhesive at the panel joints.

Hebel Systems Overview Videos
System Application System code FRL Acoustic rating Wall width
label Shaft walls adjacent to wet or common areas System code HEB 1211 Shaft to Wet FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 34dB Wall width 88mm
label Shaft walls adjacent to wet or common areas System code HEB 1212 Shaft to Common FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 33dB Wall width 88mm
label Shaft walls adjacent to wet or common areas System code HEB 1213 Shaft to Wet FRL -/120/120 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 34dB Wall width 88mm
label Shaft walls adjacent to wet or common areas System code HEB 1214 Shaft to Common FRL -/120/120 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 34dB Wall width 88mm
label Shaft walls adjacent to bathroom pod System code HEB 1454 Shaft to Bathroom pod FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr ≥25dB Wall width 145mm
label Shaft walls adjacent to dry habitable rooms System code HEB 1208 Shaft to Dry FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 40dB Wall width 131mm
label Shaft walls adjacent to dry habitable rooms System code HEB 1210 Shaft to Wet FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw+Ctr = 37dB Wall width 116mm

1 For wall heights higher than 3.3m, caged tongue & groove PowerPanel can be used and will achieve a FRL of -/120/120 for wall heights up to 4.65m (vertically).

Hebel Systems

Services Walls

Single mesh or caged Hebel PowerPanel is used in the Hebel Services Wall Systems to isolate and secure plant rooms from other areas of the building. For tall shaft risers with fire ratings up to 2 hours, PowerPanel can be installed horizontally to an unlimited height without the need for thin bed adhesive at the panel joints. Solid and secure, these systems maximise floorspace and minimise costs and risks.

Hebel Systems Overview Videos
System Application System code FRL Acoustic rating Wall width
label Services walls for walls up 3.3 metres high System code HEB 1400 Bare shaft FRL -/90/90 for wall heights up to 3.3m1 Acoustic rating Rw = 33dB Wall width 75mm
label Services walls for walls with 2 hour fire rating up to 4.65 metres high System code HEB 1207 Bare shaft FRL -/120/120 for wall heights up to 4.65 Acoustic rating Rw = 33dB Wall width 75mm

1 For wall heights higher than 3.3m, caged tongue & groove PowerPanel can be used and will achieve a FRL of -/120/120 for wall heights up to 4.65m (vertically).

Hebel Systems

High Rise Facades

Lightweight and strong, Hebel panels can be used for external facade walls in apartments with either hidden or visible edge beams.

PowerPattern offers pre-routed contemporary design collections to bring your creative vision to life.

Creating a high rise facade with Hebel provides substantial cost savings compared to traditional masonry, such as bricks, and is a popular choice with residential developers seeking style and market appeal.

 

Hebel Systems Overview Videos
System Application System code FRL Acoustic Thermal (r) values Wall width Acoustic rating
label PowerPattern Facade with hidden slab System code Hebel 1884 External to internal FRL -/120/120 external fire source only Acoustic - Thermal (r) values R3.02 - 3.47 winter
R2.82 - 3.27 summer
Wall width 230 +mm coatings
label PowerPattern Facade with visible slab System code Hebel 1885 External to internal FRL -/180/180 external fire source only - 16mm Fyrcheck required to be fixed internally Acoustic - Thermal (r) values R3.02 - 3.47 winter
R2.82 - 3.27 summer
Wall width 230 +mm coatings
label Facade with hidden slab System code HEB 2000 External to Internal FRL -/120/120 external fire source only Thermal (r) values 3.15 winter
2.94 summer
Wall width 230 +mm coatings Acoustic rating Rw+Ctr = 36dB, Rw = 45dB
label Facade with visible slab System code HEB 2001 External to Internal FRL -/180/180 external fire source only Thermal (r) values 3.15 winter
2.94 summer
Wall width 230 + coatings Acoustic rating Rw+Ctr = 36dB, Rw = 45dB

Hebel Systems

Balcony Blades

CSR Hebel has developed a fully engineered slim line balcony blade system for use in high rise residential developments. The blade design has been refined to an overall wall thickness of 200mm. This assists in maximising the usable balcony space, as well as aligning the width with internal walls – an important design aspect.

Hebel Systems Overview Videos
System Application System code FRL Acoustic rating Wall width
label Balcony blade between balconies of different SOUs System code HEB 2002 External to External FRL N/A Acoustic rating N/A Wall width 201 +mm coatings

Hebel Systems

Floors

The Hebel PowerFloor+ flooring system is a loadbearing reinforced flooring system that can span up to 5.85 metres and provides a solid, fully engineered cross-braced floor for residential and commercial construction.  Lightweight, yet strong, and offering enhanced insulation, this system can be laid in place without formwork or support and is trafficable immediately following installation.  The interlocking of panels with grout creates a full fire seal between panels, and combined with Hebel’s unique fire resistant properties, the PowerFloor+ system can achieve FRL’s of up to 3 hours without relying on ceiling systems. Once finished, the floor provides a solid base for a range of floor coverings.

Hebel Systems Overview Videos
System Application System code FRL Acoustic rating Thermal (r) values Floor thickness (mm)
label PowerFloor+ system on steel frame System code HEB 2150 FRL -/180/180 (for 200mm or 250mm thick panels from below only) Acoustic rating Rw+Ctr = 50dB (as a built up system only. Contact CSR Hebel for further details). Thermal (r) values R0.92 (150mm thick panel only at dry density) to R1.54 (250mm thick panel only at dry density) Floor thickness (mm) 150 - 250mm
label PowerFloor+ system on masonry or concrete walls System code HEB 2151 FRL -/180/180 (for 200mm or 250mm thick panels from below only) Acoustic rating Rw+Ctr = 50dB (as a built up sysem only. Contact CSR Hebel for further details). Thermal (r) values R0.92 (150mm thick panel only at dry density) to R1.54 (250mm thick panel only at dry density) Floor thickness (mm) 150 - 250mm

Hebel Stories Be inspired by the versatility of Hebel

One material, endless applications

Versatile, durable and easy to install, Hebel many applications means it can deliver a variety of building solutions for your next project.

What’s inside apartment walls counts.

As Australians embrace high-rise living, building high-quality apartment homes has never been more important. This means what’s inside apartment walls really counts. We developed the Hebel Intertenancy and Corridor Wall Systems to help builders deliver solid, durable and compliant walls for high-rise multi-residential projects. Hebel PowerPanels and the new Hebel Service Panel are at the […]

Hebel Service Panels – an innovative new building solution winning praise from industry insiders.

Hebel’s newest offering on the market, the Hebel Service Panel is receiving positive reviews before it has even hit the broader market. Designed to provide an efficient solution for multiple trades needing to install service cables, the clever thinking behind this seemingly simple product has been met with praise.

The precise appeal of Hebel

With a reputation as one of Melbourne’s leading boutique builders, Thomas Archer carefully selects materials to deliver on their modern aesthetic and distinct architectural edge. Their striking designs have won multiple awards and received acclaim for their beautiful, innovative approach.

Get instant street appeal with a mixed-material façade

Every beautifully designed home begins with a striking, decorative exterior. For instant street appeal and a house that turns heads, try creating a mixed-material façade.

ALAND harnesses the sustainable beauty of Hebel’s PowerPattern panels at Schofield Gardens.

With over 20 years of experience in the industry, ALAND has become a trusted Australian builder and developer that prioritises sustainable building practices and materials. Their Schofield Gardens project, in Sydney’s north-west, exemplifies ALAND’s dedication to creating innovative, affordable housing that has a positive impact on the community. Six stages have been completed since construction […]

Why Chasecrown’s award-winning EI8HT project pushes building standards to new heights with the help of CSR Hebel.

With a reputation for delivering high quality and innovative builds through an end-to-end approach, it’s the detail that sets Chasecrown apart as one of Adelaide’s leaders in multi-residential and commercial design. Originally established 30 years ago as an architectural firm, Chasecrown has evolved into a multi-disciplinary practice that sees them involved and managing every stage […]

Downloads


To learn more about our products and systems, search the categories below to view our range of Hebel guides, manuals, brochures and files.

View all Downloads
  • Design & Installation
  • Construction Details
  • Brochures
  • Technical Manuals
  • CAD Files
  • SDS Files
  • Codemark Certificates
  • Videos
Brochures

Hebel Service Panel brochure

DOWNLOAD EMAIL
Hebel Service Panel brochure
prev
Next
SDS Files

Hebel Safety Guide - Silica fact sheet

DOWNLOAD EMAIL
Hebel Safety Guide - Silica fact sheet
prev
Next
Construction Details

50mm Hebel Horizontal Facade Public (Rev E) Construction Detail

DOWNLOAD EMAIL
50mm Hebel Horizontal Facade Public (Rev E) Construction Detail
Codemark Certificates

PowerPanel 50mm (High-Rise Facade)

DOWNLOAD EMAIL
PowerPanel 50mm (High-Rise Facade)
CAD Files

PowerPattern Organic Collection CAD Files

DOWNLOAD EMAIL
PowerPattern Organic Collection CAD Files
prev
Next
Design & Installation

High Rise Apartments Student Accommodation Hotels Commercial
Design & Installation Guide

DOWNLOAD EMAIL
High Rise Apartments Student Accommodation Hotels Commercial <br>Design & Installation Guide
Technical Manuals

Hebel Tech Man - Pt1 Products

DOWNLOAD EMAIL
Hebel Tech Man - Pt1 Products

FAQ's

Q. How do you cut Hebel panels?

Panels can be cut using a circular saw with a diamond tipped blade. It is good practice to have a dust extraction vacuum attached to the circular saw to remove as much dust as possible. See the CSR Material Safety Data Sheets in the Downloads section for more information on dust from cutting Hebel autoclaved aerated concrete (AAC).

Q. How do I repair damaged panel sections?

Most small indentations in panels for internal wall systems - to a nominal size of 100x100x20mm deep - can be patched using Hebel Patch.

Q. Can I use Hebel Adhesive at the base of the panels instead of Hebel Mortar for internal walls?

Yes, as long as the gap at the base of the panel with the concrete slab is less than 3mm.

Q. Can plasterboard linings be glued to the Hebel panels for internal walls?

No. Plasterboard should be directly screwed to the panels to ensure there is no gap between the panel and the plasterboard, which can occur if plasterboard sheets are glued to the Hebel panels. Glueing can adversely affect the acoustics.

Q. Can I chase cables and pipes into the Hebel PowerPanel wall construction for internal walls?

It is a condition of the NCC that no chasing is allowed except for small areas to allow cabling through GPOs.

Q. Can I install lintel panels vertically, or do they need to be installed horizontally for internal walls?

All lintel panels above a door should be installed horizontally.

Q. What is the minimum door nib width for internal walls?

The panel either side should be no less than 300mm. If it is less and has a concrete column next to it, then an angle and fixings can be fixed. However the width should be no less than 150mm for that detail..

Q. What is the maximum wall height possible using 75mm tongue and groove PowerPanels for internal wall systems?

4.65 metres, where panels are installed vertically between concrete slabs, fixed top and bottom.

Q. What is the maximum width I can cut out of a vertical panel for internal walls?

A maximum of one third the panel width can be cut out of a full width panel i.e 200mm wide from a 600mm wide panel.

Q. Can I form a large opening in a Hebel internal wall?

Yes, large openings can be formed in a wall. However, anything larger than 200mm x 200mm should extend over two PowerPanels. Note that larger openings will need to be trimmed with steel angle sections

Q. Is it best practice to install services before or after the Hebel internal wall installation?

Services are best installed after the Hebel installation to allow for neat holes to be drilled into the Hebel making it easier to fire rate.

Q. Do I need to use fire rated GPOs with the Hebel tongue and groove internal wall systems?

No.  You don’t need fire rated GPOs as the Hebel PowerPanel wall construction is the component of the wall system that provides the fire performance.

Q. What is the detail required around pipe penetrations in internal walls? Do I need an annular joint or can the Hebel be hard up to the pipe/fire collar?

There should be a nominal 10mm gap around any service penetration to allow for fire rated sealant to be installed to the manufacturer’s specifications.

Q. Do I need to run the plasterboard linings up to the concrete soffit to satisfy acoustic requirements for Hebel internal wall systems?

Not to achieve NCC performance compliance. This means there’s improved installation efficiency without the need for another set joint.

Q. Do I need to extend the insulation up to the concrete soffit to satisfy acoustic requirements for Hebel internal wall systems?

Wherever insulation is shown Hebel construction details then it needs to be installed to the full height from slab to soffit, either within the stud or furring channel cavities.

Q. Do I need to install insulation in the smaller cavities when using furring channels to one side of the Hebel PowerPanel wall construction for internal walls?

Yes you do if required in the specification.  Further, it will help with acoustic performance.

Q. Can a 75mm Hebel PowerPanel wall construction achieve an FRL value of -/90/90 without any plasterboard linings for internal walls?

Yes it can for wall heights up to 3.3 metres using 75mm single mesh tongue and groove PowerPanel.

Q. How do I achieve an FRL of -/120/120 using 75mm Hebel PowerPanels for internal wall systems?

There are two ways. One is by using the 75mm caged tongue and groove Hebel PowerPanels which will achieve an FRL of -120/120 up to 4.65 metres. The other is by fixing 13mm Fyrecheck full height to single mesh tongue and groove panels for wall heights up to 3.3 metres. Proper installation of the head steel angle and sealants at the slab soffit is paramount to maintaining the fire performance

Q. Can I use standard plasterboard with the PowerPanel tongue and groove systems and still achieve an FRL of -/90/90 or -/120/120 for internal walls?

Yes you can. The fire-rating of the wall system is achieved through the PowerPanel wall construction without the need for plasterboard. For an FRL of -/90/90 use 75mm single mesh T&G PowerPanel. For an FRL of -/120/120 use 75mm caged T&G PowerPanel.

Q. Does the plasterboard need to extend to the concrete soffit to achieve an FRL of -/90/90 or -/120/120 for Hebel internal wall systems?

Only if using 75mm single mesh T&G Hebel PowerPanels up to 3.3 metres.  13mm Fyrechek is required to be direct fixed to the panel to achieve FRL of -/120/120.

Installing with Hebel

Installing Hebel internal wall systems is simple and fast - with easy to achieve NCC compliance.

Let's Explore
CSR

CSR Group Privacy Policy | CSR Group Cookie Policy | CSR Group Website Terms of Use | © 2024 Copyright Hebel.

Top